14:54 on Mon 13/Dec/04

I am trying to fit a ceiling light. The new light has a power block with markings N L and E, my problem is I cant understand the main cabling structure to the lght. I have 3 red wires twisted together, 2 black twisted together and 1 single black.


Can you advise what set of caables goes where.

Please describe this clip for users who are unable to view You Tube videos, this is for their benefit.

Type your answer here
I want to subscribe to this thread

1 to 6 of 6

Avatar Image
finex
(15:52 on Mon 13/Dec/04)

I would advise you to get an electrician in to do it. Seriously. Fitting a ceiling light might cost you as little as a tenner and you know it's not going to blow the house up!

 

It sounds like you have a light that's either controlled by multiple switches, or it's part of a series of lights on the same circuit. This may help:

http://www.diydoctor.org.uk/projects/lights_and_switches.htm

 

But bear in mind the warning on the page. Failure to have electrical work checked by a qualified electrician may invalidate your home insurance. And if you've got to get a sparky to check it, you might as well ask him tto fit it in the first place!

 

Sorry if I sound like a killjoy. I love DIY, but electrics are the one area I always get a professional in for. I don't like the idea of something that I can't see, smell or touch being able to kill me if I get it wrong!

Good luck!

Avatar Image
peanut
(16:17 on Mon 13/Dec/04) well said FINEX. it does seem like a three way switch on that light. and also where is the white wire?
Avatar Image
Tweed
(18:39 on Mon 13/Dec/04) I'm guessing that the single black is being used as a switchwire, something that a lot of electricians used to do, though they're supposed to indicate this by taping a piece of red insulation tape onto it. If that is the case, then this goes to the L on the block, the two black connects to N, and earth to E. Use a seperate connector block to connect the three reds together.
Avatar Image
Tweed
(18:41 on Mon 13/Dec/04) Check the switch and if there is a black there, then wire it as I suggested.
Avatar Image
drbsparks
(20:34 on Mon 13/Dec/04) All of the previous answers are pretty close to the mark although, peanut a WHITE wire? I've been in the electrics game now for 15 years and never seen a white wire. Basically Tweed is right. The single black will be the switch wire and should be connected into the L terminal. The collection of black wires go to the N and the reds all need to go into either a seperate connector which is not connected to anything or on some light fittings you may find a connector marked LOOP this is used for this purpose of interconnecting permanent live cables together. PLEASE make sure if the fitting is a metal cased fitting that you connect an earth wire for obvious reasons. However, after telling you all of this, please consider getting a qualified sparky to come and test it for you, electrics is more dangerous than gas in the home at least you can smell gas!!!!!
Avatar Image
peanut
(21:59 on Mon 13/Dec/04) sorry drbsparks i should have specified. about the white wire, i live in the us here we use white (neutral), black (hot), and then earth (ground).